BMSER

MODULAR ENERGY SYSTEMS

10-foot energy systems for demanding European applications

BMSer ENERGY SA develops modular energy-storage and charging configurations for industrial operations, critical digital infrastructure and application-specific mobility projects. System design, compliance and site integration are confirmed on a project-specific basis.

Product Documentation

Review the current BMSer product portfolio and technology positioning.

Download Product Brochure

MULTI-SOURCE RESILIENT POWER

FAST HUB

Multi-Source Hybrid Power System

252–505 kWh · 260–520 kWGrid · Solar · Hydro · DieselExplore FAST HUB
BMSer FAST HUB green hybrid power system

SODIUM-ION DC ENERGY STORAGE

SODIUM HUB — DC CORE 1100

A 10-foot modular sodium-ion DC energy-storage platform for project-specific energy architectures where transport, site access and scalable deployment matter.

Validated sodium-ion cell platform · European system compliance pathway

Discuss a DC storage project
SODIUM HUB — DC CORE 1100
Rated energy1.1 MWh
Cell platformNFPP sodium-ion
CoolingLiquid cooling
Rated DC power0.5P
CommunicationsModbus / IEC 60870-5-104 / MQTT / CAN
EnclosureIP55
Operating temperature-40°C to +60°C
Approximate dimensions2991 × 2438 × 2896 mm

Technical information is indicative. Final operating conditions, system configuration and compliance requirements are confirmed during project engineering.

EUROPEAN COMPLIANCE & CERTIFICATION

VALIDATED AT CELL LEVEL.ENGINEERED FOR EUROPE.

Built on a commercially mature sodium-ion cell platform with established international safety and transport validation.

The sodium-ion cells selected for the DC CORE platform are supported by UN 38.3 transport safety documentation and IEC 62619:2022 industrial battery safety documentation.

From this validated cell foundation, BMSer integrates chip-level active balancing, battery management, DC architecture and system engineering into a complete energy-storage platform for European applications.

Final system-level conformity assessment, technical documentation and project-specific certification are completed according to the delivered configuration, application and destination market.

01

VALIDATED CELL PLATFORM

International cell-level safety and transport documentation.

02

BMSER SYSTEM ENGINEERING

Active balancing · BMS · DC architecture · System integration

03

EUROPEAN PROJECT COMPLIANCE

Configuration-specific conformity, documentation and third-party verification.

UN 38.3

TRANSPORT SAFETY

CELL PLATFORM · VALIDATED

International transport safety testing for the selected sodium-ion cell platform.

IEC 62619:2022

INDUSTRIAL BATTERY SAFETY

CELL PLATFORM · DOCUMENTED

Industrial battery safety documentation supporting the selected sodium-ion cell platform.

CE

EU CONFORMITY

SYSTEM LEVEL · PROJECT-SPECIFIC

Conformity assessment and technical documentation aligned with the final European system configuration.

RoHS

RESTRICTED SUBSTANCES

CONFIGURATION · APPLICABLE

Applicable material and component conformity addressed according to the delivered system configuration.

THIRD-PARTY

INDEPENDENT VERIFICATION

PROJECT REQUIREMENT

Independent testing and verification can be incorporated according to project, customer and market requirements.

TECHNICAL FILE

EUROPEAN DOCUMENTATION

SYSTEM LEVEL · CONFIGURED

Technical documentation, conformity records and project deliverables assembled around the final system configuration.

Illustrative application. Final configuration, site integration and operating conditions are project-specific.

HIGHER-ENERGY MODULAR DC STORAGE

SODIUM HUB — DC CORE 1400

A higher-energy 10-foot sodium-ion DC energy-storage platform designed for modular industrial and grid-side energy architectures.

Validated sodium-ion cell platform · European system compliance pathway

Explore modular storage design
SODIUM HUB — DC CORE 1400
Rated energy1.4 MWh
Cell platformNFPP sodium-ion
CoolingLiquid cooling
Rated DC power0.5P
CommunicationsModbus / IEC 60870-5-104 / MQTT / CAN
EnclosureIP55
Operating temperature-40°C to +60°C
Approximate dimensions2991 × 2438 × 2896 mm

Technical information is indicative. Final operating conditions, system configuration and compliance requirements are confirmed during project engineering.

EUROPEAN COMPLIANCE & CERTIFICATION

VALIDATED AT CELL LEVEL.ENGINEERED FOR EUROPE.

Built on a commercially mature sodium-ion cell platform with established international safety and transport validation.

The sodium-ion cells selected for the DC CORE platform are supported by UN 38.3 transport safety documentation and IEC 62619:2022 industrial battery safety documentation.

From this validated cell foundation, BMSer integrates chip-level active balancing, battery management, DC architecture and system engineering into a complete energy-storage platform for European applications.

Final system-level conformity assessment, technical documentation and project-specific certification are completed according to the delivered configuration, application and destination market.

01

VALIDATED CELL PLATFORM

International cell-level safety and transport documentation.

02

BMSER SYSTEM ENGINEERING

Active balancing · BMS · DC architecture · System integration

03

EUROPEAN PROJECT COMPLIANCE

Configuration-specific conformity, documentation and third-party verification.

UN 38.3

TRANSPORT SAFETY

CELL PLATFORM · VALIDATED

International transport safety testing for the selected sodium-ion cell platform.

IEC 62619:2022

INDUSTRIAL BATTERY SAFETY

CELL PLATFORM · DOCUMENTED

Industrial battery safety documentation supporting the selected sodium-ion cell platform.

CE

EU CONFORMITY

SYSTEM LEVEL · PROJECT-SPECIFIC

Conformity assessment and technical documentation aligned with the final European system configuration.

RoHS

RESTRICTED SUBSTANCES

CONFIGURATION · APPLICABLE

Applicable material and component conformity addressed according to the delivered system configuration.

THIRD-PARTY

INDEPENDENT VERIFICATION

PROJECT REQUIREMENT

Independent testing and verification can be incorporated according to project, customer and market requirements.

TECHNICAL FILE

EUROPEAN DOCUMENTATION

SYSTEM LEVEL · CONFIGURED

Technical documentation, conformity records and project deliverables assembled around the final system configuration.

Illustrative application. Final configuration, site integration and operating conditions are project-specific.

STORAGE + HIGH-POWER DC CHARGING

CHARGE HUB — CUBE 1200

A 10-foot integrated LiFePO4 storage and DC-charging platform for demanding commercial, industrial and mobility applications, including remote or infrastructure-constrained operating environments.

Discuss a charging project
CHARGE HUB — CUBE 1200
Rated energy1.2 MWh
Cell typeLiFePO4
CoolingLiquid cooling
Maximum DC charger power600 kW
DC charging voltage range200–1000 Vdc
Vehicle interfaceCCS2
Grid input charging power160 kW
AC output power80 kW
EnclosureIP55
Operating temperature-15°C to +50°C
Approximate dimensions2991 × 2438 × 2896 mm

EUROPEAN COMPLIANCE

ENGINEERED FOR EUROPEAN DEPLOYMENT.

European conformity is built into the delivery architecture.

CUBE 1200 is engineered around a defined European compliance framework covering the battery system, power conversion, high-power DC charging, EMC, communications and environmental requirements.

For each commercial deployment, the final conformity package is completed against the ordered system configuration and destination market, with applicable testing, technical documentation and declarations integrated into the project delivery scope.

The compliance framework is designed to support deployment from system configuration and design freeze through independent verification, documentation and European site delivery.

CE

EUROPEAN CONFORMITY

INTEGRATED INTO DELIVERY

Final conformity assessment and technical documentation completed against the ordered European system configuration.

IEC / EN 62619

INDUSTRIAL BATTERY SAFETY

EUROPEAN COMPLIANCE FRAMEWORK

Battery-system safety requirements addressed within the final project certification scope.

IEC / EN 63056

ENERGY STORAGE BATTERY SAFETY

EUROPEAN COMPLIANCE FRAMEWORK

Energy-storage battery safety requirements incorporated into the system validation pathway.

EN 61851

DC CHARGING SAFETY & EMC

CHARGING SYSTEM COMPLIANCE

Applicable DC charging safety, communication and EMC requirements addressed according to the final charging configuration.

UN 38.3

BATTERY TRANSPORT SAFETY

TRANSPORT COMPLIANCE

Battery transport documentation incorporated into the European logistics and delivery framework.

RoHS · REACH

ENVIRONMENTAL COMPLIANCE

EUROPEAN MATERIAL REQUIREMENTS

Applicable restricted-substance and environmental requirements addressed within the delivered configuration.

VIEW COMPLIANCE FRAMEWORK
PCS SAFETYEN 62477-1
BATTERY + BMSEN 62619 · EN 63056
DC CHARGINGEN 61851-1 · EN 61851-23 · EN 61851-24
CHARGING EMCEN 61851-21-2
SYSTEM EMCEN 61000-6-2 · EN 55032 / EN 55035
BATTERY TRANSPORTUN 38.3
ENVIRONMENTALRoHS · REACH
EU BATTERY FRAMEWORKEU 2023/1542
01

CONFIGURE

Application · Destination market · System options

02

DESIGN FREEZE

Battery · PCS · DC/DC · Charging architecture · Communications

03

VERIFY

Applicable EN / IEC testing · EMC · Transport requirements · Independent conformity assessment

04

DOCUMENT

Technical file · Test documentation · Declarations · Project conformity package

05

DEPLOY

European delivery · Site commissioning support · Local acceptance coordination

Illustrative application. Final configuration, site integration and operating conditions are project-specific.